  <?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>vitrabondg2 - Fairview Architectural North America</title>
	<atom:link href="https://fairview-na.com/tag/vitrabondg2/feed/" rel="self" type="application/rss+xml" />
	<link>https://fairview-na.com</link>
	<description>Vitrabond G2 - Vitrabond - Arrowhead - Vitraplate - Vitraedge</description>
	<lastBuildDate>Mon, 23 Dec 2024 16:36:28 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0.4</generator>

<image>
	<url>https://fairview-na.com/wp-content/uploads/2020/02/cropped-FVA_Icon_Corporate-favicon-512x512-1-2-32x32.jpg</url>
	<title>vitrabondg2 - Fairview Architectural North America</title>
	<link>https://fairview-na.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Vitraplate® Non-Combustible Aluminum Façade Materials</title>
		<link>https://fairview-na.com/vitrabondg2-and-vitraplate-non-combustible-aluminum-facade-materials/</link>
		
		<dc:creator><![CDATA[Victoria Tayler]]></dc:creator>
		<pubDate>Wed, 18 Dec 2024 15:15:08 +0000</pubDate>
				<category><![CDATA[Blogs]]></category>
		<category><![CDATA[Product News]]></category>
		<category><![CDATA[Technical Bulletins]]></category>
		<category><![CDATA[Vitrabond]]></category>
		<category><![CDATA[ACM]]></category>
		<category><![CDATA[Aluminum Composite Material]]></category>
		<category><![CDATA[MCM]]></category>
		<category><![CDATA[Metal Composite Material]]></category>
		<category><![CDATA[non-combustible]]></category>
		<category><![CDATA[non-combustible cladding]]></category>
		<category><![CDATA[vitrabondg2]]></category>
		<category><![CDATA[Vitraplate]]></category>
		<guid isPermaLink="false">https://fairview-na.com/?p=2630</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[<div class="et_pb_section et_pb_section_0 et_section_regular" >
				
				
				
				
				
				
				<div class="et_pb_row et_pb_row_0">
				<div class="et_pb_column et_pb_column_4_4 et_pb_column_0  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_text et_pb_text_0  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><p><strong>How Does the Building Code Define Vitraplate® as Non-Combustible?</strong><br /><span data-contrast="none" xml:lang="EN-US" lang="EN-US" class="TextRun SCXW256238786 BCX0"><span class="NormalTextRun SCXW256238786 BCX0">The International Building Code (IBC) Section 703.4 </span><span class="NormalTextRun SCXW256238786 BCX0">establishes</span><span class="NormalTextRun SCXW256238786 BCX0"> the criteria for </span><span class="NormalTextRun SCXW256238786 BCX0">determining</span><span class="NormalTextRun SCXW256238786 BCX0"> a product&#8217;s non-combustibility. This definition is necessary, as ASTM E-136, a standard test for non-combustibility, is primarily applicable to elementary materials rather than manufactured or painted products such as <a href="https://fairview-na.com/fairviews-products/vitraplate-3/">Vitraplate</a></span><span class="NormalTextRun SCXW256238786 BCX0"><a href="https://fairview-na.com/fairviews-products/vitraplate-3/">®</a>.</span></span><span class="EOP SCXW256238786 BCX0" data-ccp-props="{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;201341983&quot;:0,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335557856&quot;:16777215,&quot;335559685&quot;:0,&quot;335559737&quot;:0,&quot;335559738&quot;:0,&quot;335559739&quot;:0,&quot;335559740&quot;:259}"> </span></p>
<p><strong> Does Vitraplate® pass the ASTM E-136 test to prove that they are non-combustible?</strong><br />The ASTM E-136 test is for elementary materials only and is therefore not for any painted product. As such, the aluminum used in Vitraplate® passes the ASTM E-136, meaning that Vitraplate® non-combustible.</p>
<p><strong>Has Vitraplate® passed an NFPA 285 full scale wall assembly fire test?</strong><br />The NFPA 285 test does not apply to <a href="https://fairview-na.com/fairviews-products/vitraplate-3/">Vitraplate®</a>. It also does not apply to the non-combustible wall assembly applications where we recommend using <a href="https://fairview-na.com/fairviews-products/vitraplate-3/">Vitraplate®</a>. The NFPA 285 is specifically made for combustible products, to allow their use in wall assemblies that are meant to use products rated as non-combustible according to the building code. Fairview Architectural has many products for many applications. Other MCM/ACM manufacturers with a single product range must try to make their product fit where it shouldn’t. By contrast, Fairview promotes <a href="https://fairview-na.com/vitrabond-fr/">VitrabondFR®</a> where wall assemblies are permitted to contain combustible products and promotes Vitraplate® for use in non-combustible wall assemblies.</p>
<p><strong>Why not have Vitraplate® tested in an NFPA285 wall assembly test? Wouldn’t that open up a greater market share?</strong><br />It is not about market share – we simply develop the RIGHT product for the RIGHT application, and don’t try to promote saving pennies at the cost of life safety. Fairview Architectural was the first to discontinue the use of the flammable PE core ACM, and the first to develop non-combustible pre-finished solid aluminum building façade material, known as <a href="https://fairview-na.com/fairviews-products/vitraplate-3/">Vitraplate®</a>.</p>
<p><strong>Is there a full-scale wall assembly fire test for Vitraplate® in North America?</strong><br />At this time non-combustible products themselves are not required to undergo full-scale wall assembly testing, and there are no full-scale fire tests for non-combustible products in the North American market. Fairview Architectural ensures that our products meet and exceed the testing criteria for the applications they are designed for, and invest into the development of the right product for each application.</p>
<p><strong>Are other fire tests such as ASTM E-119 or ASTM E-84 required for Vitraplate®?</strong><br />Many tests, such as ASTM E84 are used to determine the risk of using combustible products in construction. Specifically, ASTM E84 is to determine the surface burning characteristics of building materials. As <a href="https://fairview-na.com/fairviews-products/vitraplate-3/">Vitraplate®</a> is classified as a non-combustible product according to ASTM E-136 and IBC Section 703.4, there is no surface burning, so ASTM E84 is not required by the building codes, nor is it applicable to the product.</p>
<p>Likewise, ASTM E119 as relates to walls is a test used for determining how long a fire can be prevented from passing through a wall assembly. An example of this is when you have a partition wall between a garage and living space, some codes require double 5/8” Type X gypsum to achieve a 2 hour rated wall. As a cladding material, there is no correlation between <a href="https://fairview-na.com/fairviews-products/vitraplate-3/">Vitraplate®</a> and the ASTM E119 standard, therefore there is no way to perform this test according to the test standards and the use of the product.</p>
<p><strong>Conclusion</strong></p>
<p>We envision a building façade industry free of flammable cladding materials. We all understand that buildings need paint, adhesives, waterproofing, paper backers on drywall, etc… and we are working with conscientious insurers, code consultants, fire marshals, and architects who have embraced our vision as together we lead the change to a safer building façade industry.</p></div>
			</div>
			</div>
				
				
				
				
			</div>
				
				
			</div><p>The post <a href="https://fairview-na.com/vitrabondg2-and-vitraplate-non-combustible-aluminum-facade-materials/">Vitraplate® Non-Combustible Aluminum Façade Materials</a> first appeared on <a href="https://fairview-na.com">Fairview Architectural North America</a>.</p>]]></content:encoded>
					
		
		
			</item>